Details
-
Fix
-
Status: Dismissed (View Workflow)
-
Major
-
Resolution: Duplicate
-
2.5.7
-
None
Description
Current Situation
- Controller instance C1 and Controller instance C2 are clustered and coupled.
- C1 is the active Controller instance, C2 is the standby Controller instance.
- When shutting down C2 and starting C2 again, then the Controller instances will couple.
- In this situation a switch-over from C1 to C2 is not possible. A message "BadRequestError: InvalidSessionToken: Invalid session token." is raised in JOC Cockpit's joc.log.
Desired Behavior
Switch-over should work after restart of the standby Controller instance.
Maintainer Note
- The indicated problem occurs infrequently.
- Feature
JOC-1814brings automated and manual restart of the Proxy Service in JOC Cockpit that holds the connection to Controller instances. - This issue is considered begin resolved by implicit restarts of the Proxy Service.
Attachments
Issue Links
- duplicates
-
JOC-1814 Providing an API for restarting the Controller Proxies
- Released