Monitor Service - URL Variables

    XMLWordPrintable

Details

    Description

      The Monitor Service considers two URLs used with the JS7 Notification interface:

      • The URL by which JOC Cockpit is available
        • This value can be changed in the Dashboard view, action "Update URL".
        • The new value is only available in the JS7 Notification Interface after a JOC Cockpit restart has been performed.
      • The URL to access JOC Cockpit by a proxy
        • This value can be changed in the Settings view, section joc - entry joc_reverse_proxy_url
        • The new value is available in the JS7 Notification Interface about 1 minute after the change.
        • The value joc_reverse_proxy_url is not available in the JS7 Notification Interface if a JOC Cockpit restart has been performed.

      Desired Behaviour

      • The JOC URLs should be available in the Notification Interface without restarting and should not be lost when restarting.

      Test instructions

      • Configure a MailFragment
      • Configure a CommandFragment
        • Use a “set” command on Windows, for example, to get all environment variables
      • Test the Notification and SystemNotification
        • Note: In the SystemNotification interface, the variables JOC_REVERSE_PROXY_HREF{_}... are not available – use Common JOC Cockpit Variables instead
      • Test if the values ​​are populated and available without restarting JOC Cocpit and if they not lost after restart